Hinweis Dies ist nicht die aktuellste Version der Ressource. Diese kann hier gefunden werden: https://fordatis.fraunhofer.de/handle/fordatis/286.2
Langanzeige der Metadaten
DC ElementWertSprache
dc.contributor.authorEl-Safoury, Mahmoud-
dc.contributor.authorWeber, Christian-
dc.contributor.otherYassine, Hassan-
dc.contributor.otherWöllenstein, Jürgen-
dc.contributor.otherSchmitt, Katrin-
dc.date.accessioned2022-09-29T09:51:45Z-
dc.date.available2022-09-29T09:51:45Z-
dc.date.issued2022-
dc.identifier.urihttps://fordatis.fraunhofer.de/handle/fordatis/286-
dc.identifier.urihttp://dx.doi.org/10.24406/fordatis/215-
dc.description.abstractMeasured microphone and NDIR detector signalsen
dc.language.isoenen
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/en
dc.subjectCO2 measurementen
dc.subjectPhotoacoustic sensoren
dc.subjectCommercial NDIR sensoren
dc.subject.ddcDDC::600 Technik, Medizin, angewandte Wissenschaften::600 Technik::600 Technik, Technologieen
dc.titleTowards a miniaturized photoacoustic sensor for application in transcutaneous CO2 monitoringen
dc.title.alternativeSupplementary dataen
dc.typeTabular Dataen
dc.contributor.funderFraunhofer-Gesellschaft FhGen
fordatis.groupLight & Surfacesen
fordatis.instituteIPM Fraunhofer-Institut für Physikalische Messtechniken
fordatis.rawdatatrueen
fordatis.date.start2022-
fordatis.date.end2022-
Enthalten in den Sammlungen:Fraunhofer-Institut für Physikalische Messtechnik IPM

Dateien zu dieser Ressource:
Datei Beschreibung GrößeFormat 
Figure6_0-30% CO2 measurement.zipComparison of the developed photoacoustic CO2 sensor with the commercial NDIR sensor ExplorIR-W (Gas Sensing Solutions Ltd., United Kingdom) at 1 vol. % concentration variations between 0 and 30 vol. % CO2. The tested gas matrix is a mixture of dry N2 and CO2. Each gas matrix variation was measured for 10 minutes in five repetitions (n=5).1,79 MBZIPÖffnen/Download
Figure7_30-70%_Humidity_influence.zipComparison of the developed photoacoustic CO2 sensor with the commercial NDIR sensor ExplorIR-W (Gas Sensing Solutions Ltd., United Kingdom) at 10 vol. % concentration variations between 30 and 70 vol. % humidified N2. The tested gas matrix is a mixture of dry and moist N2 at 8 vol. % CO2. Each gas matrix variation was measured for 10 minutes in five repetitions (n=5).574,61 kBZIPÖffnen/Download
Figure8_0-20%_Oxygen_influence.zipComparison of the developed photoacoustic CO2 sensor with the commercial NDIR sensor ExplorIR-W (Gas Sensing Solutions Ltd., United Kingdom) at 5 vol. % concentration variations between 0 and 20 vol. % O2. The tested gas matrix is a mixture of dry N2 and O2 at 8 vol. % CO2. Each gas matrix variation was measured for 10 minutes in five repetitions (n=5).533,45 kBZIPÖffnen/Download

Versionshistorie
Version Ressource Datum Zusammenfassung
2 fordatis/286.2 2024-01-10 14:06:56.164 Die Veröffentlichung, die auf diesem Datensatz basiert, wurde bei einem anderen Journal neu eingereicht. Dabei hat sich die Reihenfolge der Abbildungen/Daten verändert und es sind neue Abbildungen/Daten hinzugekommen.
1 fordatis/286 2022-09-29 11:51:45.0

Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons